plumb-mate
← Products
Pressure & Temperature Relief Valve

Pressure & Temperature Relief Valve (PTR)

Pressure & Temperature Relief Valve

Critical safety control for unvented storage water heaters—vertical or horizontal installation, lead-free bronze body, heavy-duty auxiliary relief, with insulation jacket for external use.

Key Features

  • Valve is designed to work in either vertical or horizontal installations — flexible installation options
  • Heavy duty auxiliary relief — upgraded lead-free copper auxiliary relief valve for longer life expectancy
  • Lead-free bronze body — fully compliant with the lead-free requirements of the National Construction Code Volume 3

The plumb-mate PTR valve is a critical safety control designed to protect unvented storage water heaters.

It guards against over-heating and over-pressure hazards by relieving the increase in pressure caused by water expansion during the normal heating cycle.

In the event that thermostatic controls fail and water overheats, the temperature probe activates to discharge hot water, ensuring the system does not exceed 99°C.

All products are supplied with an insulation jacket suitable for external installation.

Product Technical Data

SpecificationPMPTRE-15PMPTR-15PMPTR-20
Inlet connection
R 1/2" MaleR 1/2" MaleR 3/4" Male
Outlet (drain) connection
G 1/2" FemaleG 1/2" FemaleG 3/4" Female
Pressure ratings (kPa)
1000 / 1400700 / 850 / 1000 / 1400700 / 850 / 1000 / 1400
Expansion rating
10 kW10 kW46 kW
Special configuration — extended body
Extended body
Opening temperature range
93°C – 99°C
  • Designed and manufactured to meet AS 1357.1:2019.
  • Technical drawings: refer to product sheets for DN15 and DN20 models.
  • Watermark licence no. WMK27143.

Dimensions

Dimensions in millimetres. Call-outs A–E are shown on the product drawing.

ModelSizeInletOutletA (mm)B (mm)C (mm)
PMPTR-15
DN15R 1/2" MaleG 1/2" Female52.53495
PMPTRE-15
DN15R 1/2" MaleG 1/2" Female77.53469
PMPTR-20
DN20R 3/4" MaleG 3/4" Female52.53495

PTR and PTRE set pressures and model codes

Pressure rating15mm PTR15mm PTRE20mm PTR
700 kPa (Black)
PMPTR-15-700PMPTR-20-700
850 kPa (Blue)
PMPTR-15-850PMPTR-20-850
1000 kPa (Green)
PMPTR-15-1000PMPTRE-15-1000PMPTR-20-1000
1400 kPa (Red)
PMPTR-15-1400PMPTRE-15-1400PMPTR-20-1400

Model codes by rating plate colour

Pressure & Plate Colour15mm PTR15mm PTRE20mm PTR15mm ECV20mm ECV
Black
PMPTR-15-700PMPTR-20-700PMECV-15-600PMECV-20-600
Blue
PMPTR-15-850PMPTR-20-850PMECV-15-700PMECV-20-700
Green
PMPTR-15-1000PMPTRE-15-1000PMPTR-20-1000PMECV-15-850PMECV-20-850
Red
PMPTR-15-1400PMPTRE-15-1400PMPTR-20-1400PMECV-15-1200PMECV-20-1200

ECV and PLV selection guide

Cold inlet pressure at the ECV must not exceed 80% of the PTR relief setting on the water heater. This chart recommends the ECV pressure setting and shows when a pressure-limiting valve (PLV) is needed and at what setting.

PTR valve setting (on water heater)Recommended plumb-mate ECV settingPLV required if mains pressure exceedsPLV setting (if required)
700 kPa
600 kPa480 kPa350 kPa
850 kPa
700 kPa560 kPa350 kPa
1,000 kPa
850 kPa680 kPa500 kPa
1,400 kPa
1,200 kPa960 kPa600 kPa